Website Visits:
 |
|
 |
Central Heating Systems
|
Radiators |
| |
| |
 |
|
Royal by grupporagaini (Romania) |
| |
ROYAL
(ALUMINUM RADIATOR)
The advantages that this type of radiator offers can be found in its sturdyness, low weight, easy assembly, as well as low dimensions which make it ideal for small places and it can be used in any kind of room. With the elegant lines refinement and the best quality paint, incorruptible in time, RADOX radiators are adaptable to any decoration style. |
|
 |
| |
|
|
| Product Name |
Total Height
(mm) |
Centres
(mm) |
Depth
(mm) |
Width
(mm) |
Thermal Power
(Watt) |
| ROYAL 80 |
872 |
800 |
71 |
80 |
187 |
| ROYAL 70 |
773 |
700 |
71 |
80 |
170 |
| ROYAL 60 |
675 |
600 |
70 |
80 |
151 |
| ROYAL 50 |
575 |
500 |
70 |
80 |
132 |
| PL 80 |
875 |
800 |
90 |
80 |
219 |
| PL 700 |
775 |
700 |
90 |
80 |
198 |
| PL 60 |
675 |
600 |
90 |
80 |
175 |
| PL 50 |
575 |
500 |
90 |
80 |
151 |
| PL 35 |
425 |
350 |
90 |
80 |
110 |
| HI 180 |
1800 |
1620 |
83 |
80 |
349 |
| LW 20 |
275 |
200 |
148 |
80 |
95 |
|
| |
|
|
|
|
| |
| |
 |
|
Alarko Turkey |
| |
The line which reaches to 21'st century in panel radiator
A salon, bedroom, living room, child's room, kitchen, bath or office... All details have been considered in the careful search for an attractive decor that suits your personal taste and provides full comfort as well. From the picture on the wall to the carpet on the floor and the style of the arm chairs-every selection is important. In such a setting there is yet another, equally important
selection to be made; The Radiator.
Chic and Decorative:
Alarko steel panel radiatorslend a chic and decorative aspect to the environment in which they are placed. |
|
 |
Elegant: Alarko steel
panel radiators offer an
elegance that is
indispensable among those
who know how to
appreciate it.
Different: Alarko steel panel radiators are selected by discriminating people. This line is indeed extraordinary, a point not so easily reached-even by those who desire it!
Quality: Alarko steel panel radiators are produced and coated according to the latest technology on computer-controlled assembly lines. These highly efficient radiators are resistant to corrosion, chemicals, impact, scratches and ambient air conditions. The smooth surfaces don't collect dust, and the special covering system allows for easy cleaning.
Multiple adaptations: Alarko steel panel radiators, with their perfect designs and up-to-date production technology, are the excellent choice for use in multi-story buildings in which high operation pressure is required. The various alternative sizes available and their compactness also make them suitable for smaller environments.
Alarko steel panel radiators can also be supplied with compact valve ensuring piping connection from the bottom side. This type of radiator provides savings in heating costs, when equipped with a thermostatic regulator.
They sparkle: Alarko steel panel radiators add sparkle to their environment.
Technical Details
Types and Dimensions |
|
|
| |
| |
 |
|
Ferroli Italy |
| |
Aluminium radiators
The new, high-power, CLAN N radiators, die-cast in a special aluminium alloy, have been designed to improve convection heat emission by enlarging the convective fins in precise relation to wet surfaces. The special, low-inertia aluminium alloy cuts down the time required for the system to reach peak performance, offers high resistance to corrosion, and is lightweight - making installation extremely easy. The smaller sizes - made possible thanks to the improved performance - and the sober, elegant lines, offer the appearance and design features that enable the radiators to fit in perfectly with any style of furnishing. |
|
 |
| Models |
CLAN N 5 |
CLAN N 6 |
CLAN N 7 |
CLAN N 8 |
| Depth (mm) |
98.0 |
98.0 |
98.0 |
98.0 |
| Height (mm) |
581.5 |
681.5 |
781.5 |
881.5 |
| Distance between hubs (mm) |
500 |
600 |
700 |
800 |
| Width (mm) |
80 |
80 |
80 |
80 |
| Water content (l) |
0.40 |
0.43 |
0.48 |
0.52 |
| Weight (kg) |
1.3 |
1.5 |
1.8 |
2.0 |
| Heat output EN 442 at 50°C (Watt/elem.) |
122 |
141 |
159 |
173 |
| Heat output EN 442 at 60°C (Watt/elem.) |
155 |
179 |
203 |
220 |
|
|
|
| |
| |
 |
|
Baykan Turkey |
| |
|
The panal radiator that fits everywhere
Baykan Radiators are manufactured at TS EN 442 standards. Maxumum operating pressure is 7 bars and maximum operating temperature 110℃. Leack testes at 10,5 bars are conducted for each radiator manufactured before being deivered to customers. You can use our products manufactured for the toughest conditions for many years trouble free.
Technical Details
|
|
 |
|
|
| |
|
Fan Coil Units |
| |
| |
 |
|
C&D China |
| |
FSU 200 ~ 1200
FAN COIL UNIT FSU Series
Vertical unit with cabinet, with bottom air inlet
and top outlet, for wall installation or floor
installation with feet.
Characteristics
- Low noise
- Fin coil heat exchanger with reversible left
connections
- 3-speed fan motor
- Complete with washable polypropylene filter,
fixed louvers and condensate drain pain with
natural discharge
- Cabinet made of coated sheet metal
|
|
 |
Available Configurations
FSU 200 C R - 2 - 1
(1) (2) (3) (4)
(1) Nominal Air Volume: CFM
(2) Direction of Nozzle
L Left hand side
R Right hand side
(3) Electric Heating Power: KW
(4) Power Supply:
1 220/1/50
3 230/1/60
6 Other power supply
Optional
3-way valve
2-way valve
Mechanical controller
Digital controller (LCD screen)
Infrared remote controller
Stainless steel flexible connection pipe
Technical Details |
|
|
| |
| |
 |
|
YAIR China |
| |
| Model |
WHG- 140ZGFP |
WHG- 160ZGFP |
WHG- 200ZGFP |
WHG- 250ZGFP |
| Air flow(m3/h) |
High |
1400 |
1600 |
2000 |
2500 |
| Middle |
1200 |
1400 |
1740 |
2100 |
| Low |
900 |
1100 |
1420 |
1700 |
| Cooling capacity(W) |
High |
6360 |
7300 |
10000 |
12500 |
| Middle |
5500 |
6280 |
9000 |
11250 |
| Low |
4300 |
5160 |
7000 |
8750 |
| Heating capacity(W) |
High |
14,325 |
16,440 |
22,500 |
28,200 |
| Middle |
12,400 |
14,160 |
18,000 |
23,300 |
| Low |
9,700 |
11,640 |
15,040 |
19,500 |
| Noise db(A) |
≤50 |
≤56 |
≤56 |
≤56 |
| Cool water supply temp. |
7℃-12℃ |
| Hot water supply temp. |
70℃-50℃ |
| Power supply |
220~240V/1PH/ /50HZ, 208~230V/1PH/60HZ |
| Water pipe size |
ZG3/4 |
Product size(mm)
LWH |
500285
1700 |
520325
1760 |
620380
1910 |
620380
1910 |
| Net weight(Kg) |
38 |
45 |
56 |
65 |
| Gross weight(Kg) |
42 |
50 |
62 |
73 |
|
 |
|
|
| |
|
Boilers |
| |
| |
 |
|
Motan Start Comfort, safety and fiability at good price |
| |
Comfort, safety and fiability at good price
General characteristics
MOTAN START is a modern wall hung gas boiler which functions with natural gas or LPG, for heating and preparing domestic hot water.
MOTAN START is available in two models:
MOTAN START C11 SPV 24 MEF
- ideal for block of flats and other dwellings without gas-exhaust chimneys
- forced draft
- bithermal
- nominal power: 24 kw
- nominal power efficiency 93%
MOTAN START C11 SPV 24 ME
- for houses or dwellings with gas-released chimneys
- natural draft
- bithermal
- nominal power: 24 kw
- nominal power efficiency 93%
|
|
 |
| Type |
C11 SPV 24ME |
C11 SPV 24MEF |
| Power efficiency symbol |
*** |
*** |
| Category |
112H3B/P |
112H3B/P |
| Draft |
Natural |
Forced |
| Combustion Chamber |
Open |
Air-tight |
Nominal output efficiency
-natural gases* |
93,3%
|
93,3%
|
| Nox Class LPG* |
93,1% |
93,1% |
| -natural gases* |
4 |
4 |
| -LPG* |
1 |
3 |
| Nominal power |
24 kw |
24 kw |
| Minimum power |
10,2 kw |
10,2 kw |
| Burner nominal load |
25.28 kw |
25.28 kw |
Gas pressure
NG on coupling (after reducer) |
20 mbar
|
20 mbar
|
| NG at admitted maximum input |
35 mbar |
35 mbar |
| GPL |
30 - 37 mbar |
30 - 37 mbar |
| Electrical features |
230V/50Hz
90W |
230V/50Hz
130W |
| Weight |
37 kg |
39 kg |
| Heat exchanger capacity |
1 l |
1 l |
| NG nominal max consumption |
2.64 Nmc/h |
2.64 Nmc/h |
| GPL nominal max consumption |
2,00 kg/h |
2,00 kg/h |
| Central heating |
|
|
| Heat carrier output |
0,8 m3/h |
0,8 m3/h |
| Admitted minimum and maximum pressure |
0,5 and 3 bar |
0,5 and 3 bar |
| The temperature on the heating circuit |
30-80 0C |
30-80 0C |
Connectors
input-output central heating |
3/4"
|
3/4"
|
| DHW Input-output |
1/2" |
1/2" |
| Gas supply |
3/4" |
3/4" |
Dimensions
Length (mm) |
684
|
684
|
| Width (mm) |
416 |
416 |
| Depth (mm) |
325 |
325 |
| With fitted elbow (mm) |
- |
850 |
| Expansion vessel with membrane |
71 |
71 |
DHW preparator
DHW Temperature |
30° - 60°C
|
30° - 60°C
|
Flow values
Δ T=25°C |
13,8 l/min
|
13,8 l/min
|
| Δ T=35°C |
9,8 l/min |
9,8 l/min |
| Δ T=45°C |
7,7 l/min |
7,7 l/min |
| Pressure |
0,2 - 8 bar |
0,2 - 8 bar |
| Exhaust gases (Temperature) |
130°C 150°C |
130°C 150°C |
| Necessary negative pressure for chimney |
0,015 hPa |
0,015 hPa |
| Boiler gas pipe (inlet-outlet) |
Ø125 |
Ø100Ø60 |
| Exhaust gases pipe length |
shorter+chimney |
3m |
| Guiding values |
|
Maximum |
| Water content in installation |
150 l |
150 l |
| Maximum enclosure surface |
200 sqm |
200 sqm |
Safety systems:
- Overpressure safety valve protects the gas boiler at a pressure higher than 3 bars
- Water temperature sensors on the heating and domestic hot water circuits.
- Air pressure switch (forced draught version) which detects a possible draught deficiency and sends this information to the electronic board.
- Safety thermostat protects the heat exchanger from reaching high temperature.
- Electronical board which receives information and controls the execution elements
- Performant self-diagnostic system
- Anti freeze protection function
- Chalk deposits prevention system
- Antiblocking pump system acting at every 24h
Wall hung gas boiler MOTAN integrate Import components of the best quality:
- Grundfos circulation pump (Denmark);
- Heat exchanger Fugas / Valmex (Italy);
- Gas valve Honeywell (Holland);
- Air pressostat Honeywell (Olanda);
- Burner Worgas (Italy);
- Expansion Vessel (Italy)
- Electric fan EBMPAPST (Germany);
- Safety valve Pintossi + C (Italy);
- Electronical board Brahma (Italy);
|
|
|
| |
| |
 |
|
Motan Max Optimus Great heating power high class technology |
| |
Great heating power high class technology
Characteristics:
- Raised constant efficiency
- "Comfort DHW" function assures a high comfort by quickly responding to the domestic hot water consumer's request
- "Optimus system" permits, through a rigurous combustion control, an annual money saving of 5% in comparison with the traditional boilers.
- Reduced expenditure of electrical power
- Wall hung gas boiler easy to install due to its reduced size
- Flame electronic ignition and modulation
- Primary heat exchanger and secondary heat exchanger with 30 plates
- Continuous modulation gas valve
- Flowmeter to detect the domestic hot water debit
- NTC tempertaure sensors with ultra-fast respond on the heating and domestic hot water circuits
- 3-way gas valve
- LCD display control panel assures a highly efficient graphic interface and switch pads.
- Different work modalities for customers and plumbers as well
- Crono-thermostat and temperature external device connection option
- Gas boiler discharge valve.
- <<Comfort function>> permits the customer not to mix hot water with cold water, but only to open the hot water tap.
- Noxe low emission: NoX 4 on natural gas type and 4 on GPL type
|
|
 |
| Type |
C17 SPV 31MEF |
| Draft |
Forced |
| Combustion Chamber |
Sealed |
| Efficiency at maximum load |
93% |
| Efficiency at minimum load |
92% |
| Useful power (min/max) |
13-31kW |
| Burner nominal load (min/max) |
14,8-33, 17kW |
Gas pressure
NG on coupling (behind the reducer)
NG on maximum admitted
LPG |
20 mbar
35 mbar
30 - 37 mbar
|
| Power-supply |
230 VAC, 50 Hz |
| Powr consumption |
160 W |
| Weight |
45 Kg |
| Capacity of the heat exchanger |
1,8 L |
| NG consumption (8500 kcal/ Nm3) at useful power (max/min) |
1.4 3.34 Nm3/h |
| LPG consumption (20425 kcal/ kg) at maximum output |
0,58 1,38 Kg/h |
| Central heating |
|
| Minimum and maximum admitted pressure |
0,5 and 3 bar |
| Temperature on the heating circuit |
40 - 80°C |
Connections
Inlet outlet central heating
Inlet outlet DHW
gas supply |
3/4"
1/2"
3/4"
|
Dimensions
Depth (mm)
Width (mm)
Height (mm)
With mounted elbow (mm) |
325
435
730
880
|
| Expansion vessel with membrane |
8 L |
DHW preparator
DHW temperature range |
30 - 60°C
|
Flow values
t = 25°C
t = 35°C
t = 45°C |
17.8 l/min
12.7 l/min
9.91 l/min
|
| Domestic cold water pressure |
0.2 - 8 bar |
| Exhaust gases temperature at rated output |
147°C |
| Burned gases connection (input-output) |
Ø100/Ø60 |
| Burned gases connection length |
Maximum 3 m |
Orientative values
Maximum water content in the installation
Maximum surface of the precinct |
200 l
250 sqm
|
Safety systems:
- Overpressure safety valve protects the gas boiler at a pressure higher than 3 bars
- Water temperature sensors on the heating and domestic hot water circuits.
- Air pressure switch (forced draught version) which detects a possible draught deficiency and sends this information to the electronic board.
- Safety thermostat protects the heat exchanger from reaching high temperature.
- Electronical board which receives information and controls the execution elements
- Self-diagnostic performant system
- Anti freeze protection function
- Chalk deposits prevention system
- Antiblocking pump system with acting at every 24 hour
Wall hung gas boiler MOTAN integrate import components of the best quality:
- Grundfos circulation pump (Denmark);
- Heat exchanger Fugas / Valmex (Italy);
- Gas valve Honeywell (Holland);
- Air pressostat Honeywell (Olanda);
- Burner Worgas (Italy);
- Expansion Vessel (Italy)
- Electric fan EBMPAPST (Germany);
- Safety valve Pintossi + C (Italy);
- Electronical board Brahma (Italy);
|
|
|
| |
| |
 |
|
Motan Storage Tank High DHW comfort |
| |
High DHW comfort
Characteristics:
- The storage tank is made from stainless steel, this fact assure 10 years medium lifetime through the corrosion resistance;
- Must be attached to a boiler which produce domestic hot water;
- Results an assembly: gas boiler - storage tank with a Superior efficiency and an utilization at a larger scale: can be coupled at bithermal and monothermal boilers;
- Storage and maintain the setting temperature of domestic hot water;
- Compact product which incorporate the safety elements: expansion vessel (8l), safety valve (8 bar) and control elements: control panel (composed from an thermostat and a thermometer) and temperature sensors;
- Supplementary anti-corrosion protection, assured by magnesium anode, which have the role of Ca and Mg ions attracting;
- The user needs only to connect the storage at the gas boiler, because of incorporated elements and accessories.
|
|
 |
| Name |
Storage tank DHW |
| Type: |
BA120LPV |
| Maximum level of noise: |
< 50 dB(A) |
| Capacity of storage domestic hot water: |
120 litri |
| Maximum pressure of domestic hot water: |
8 bar |
| Test hydraulic pressure: |
12 bar |
| Recommended maximum input pressure: |
5 bar |
| Maximum DHW Temperature: |
65°C |
| Flow values domestic hot water: |
16.5 l/min.
(ΔT = 30°C) |
| Storage minimum temperature: |
5°C |
| Expansion vessel with membrane |
8 litri |
| Electric characteristics: |
230V/50Hz
- 135W |
| Net weight (without water): |
61 kg |
| Gross weight (with water): |
181 kg |
Connections:
Inlet domestic cold water
Outlet domestic hot water
Outlet/Inlet circulating water |
3/4"
3/4"
3/4"
|
Dimensions:
Depth (mm)
Length (mm)
Height (mm) |
633
500
1105
|
|
|
|
| |
| |
 |
|
Only Heating Blowtherm (Italy) |
| |
Blowtherm wall boilers with low NOx operate both with natural and LPG gas, and are equipped with the accessories necessary for exceptional efficiency in the heating and production of sanitary hot water.
Water storage wall boilers are ideal for contemporary applications. Minimum operating pressure is 0.2 bar. At the start of the boiler the water is immediately hot, due to the patented double exchanger system.
The direct firing wall boilers are equipped with a special micro accumulator device (4 liters), which enables the usage of hot water in a very short and continuous period. They are also equipped with electronic ignitions.
Installation is particularly easy because of the extremely compact size and extreme simplicity in connecting the system using the vertical water attachments, adaptable to most any solution.
They are available in versions (2-3 star) both with open chamber or with airtight chamber and conformed to the efficiency norms 92/42 EEC.
|
|
 |
| |
|
|
| Models |
RRE 22 |
RRE 27 |
RRE 32 |
| Maximum rated input |
kW (kcal/h) |
26.60 (22900) |
29.80 (25628) |
34.50 (29670) |
| Minimum rated input |
kW (kcal/h) |
12.80 (11008) |
17.50 (15050) |
19 (16340) |
| Maximum rated output |
kW (kcal/h) |
23.94 (20588) |
26.67 (22937) |
31.91 (27445) |
| Minimum rated output |
kW (kcal/h) |
10.90
(9374) |
15.06 (12951) |
16.93 (14559) |
| 100% out efficiency |
% |
90 |
89.5 |
92.5 |
Heating temperature setting
(min - max) |
oc |
30 - 80 |
30 - 80 |
30 - 80 |
| Maximum heating working temperature |
oc |
80 |
80 |
80 |
| Maximum heating working pressure |
bar |
3 |
3 |
3 |
| Minimum heating working pressure |
bar |
0.3 |
0.3 |
0.3 |
| Expansion vessel capacity |
Liters |
8 |
8 |
8 |
| Electrical connection |
V/Hz |
230/50 |
230/50 |
230/50 |
| Power supply |
W |
120 |
120 |
120 |
| Electrical protection degree |
IP |
IPX4D |
IPX4D |
IPX4D |
| Width |
mm |
450 |
450 |
450 |
| Height |
mm |
800 |
800 |
800 |
| Depth |
mm |
320 |
320 |
320 |
| Weight |
kg |
38 |
38 |
39 |
|
| |
|
|
|
|
| |
| |
 |
|
Alarko Oil and Gas-Fired Cast Iron Boiler |
| |
Varied Options:
23 models with capacities between 65.000-800.000 Kcal/hour.
Elastic Casting Technology:
Cast iron panel boilers are produced by using Elastic Casting Technology provided by special alloys of EN GJL 200 material. The resistant of the cast sections against to thermal shocks is increased to high levels by the special alloy materials used at cast production.
Environmentally Friendly:
With its special designed combustion chamber perfect conditions of combustion and lowest values for emission rates.
|
|
 |
3 Pass Flue Gas System:
3 Pass Flue Gas System Most efficient burnery is attained by forcing flames & combustion gases to flow through 3 independent parts of heat transfer volumes. Flow through low temperature combustion chamber allows low NOx values to be attained than regular boiler systems.
Insulation:
By covering the iron cast boiler sections with 80 mm glass wool including aluminum folio coating perfect insulation is provided. By using ceramic fiber insulation material with 1300°C resistant at the front cover the high temperature may occur here is prevented.
Combustion Chamber:
With special designed winglets inside the combustion chamber and combustion gas pipes the heat transmission surfaces are increased and so by maximization of the heat transmission boiler output is increased.
Perfect Compatible Operation With Gas/Diesel Fuel Burners:
Full operating compatibility with standards, gas, diesel and fuel oil burners and efficient operating.
Flame Monitoring:
Monitoring of the burner flame without opening the front cover is possible by monitoring glass resistant against high temperature.
Easy Installation:
Because the cast iron boilers can be carried as slices to the boiler room, it does not create a problem, such as destruction of any wall. The installation is very easy. Simple and Easy
Maintenance:
Because the front cover can be removed from front side it makes simpler the maintenance.
Full Quality Control:
The boiler panels were tested 100% at 8-10 bars.
Guarantee:
The cast iron boilers are under the 5 years guarantee of manufacturer for the production defects.
Technical Details
|
|
|
| |
| |
 |
|
Alarko Oil and Gas Fired Steel Boiler |
| |
Product of advanced technology:
Entire production, design techniques and materials used comply with both European and national standards. Latest automation techniques such as CNC Punch Press, CNC Plasma Cutting, NC Welding Robots and NC bending are employed in the production processes.
High efficiency:
Highest Boiler efficiency is attained by use of large volume combustion chamber, maximising heat transfer surfaces. Boiler gas & water side resistances stand by time losses are minimised and European NOx norms are achieved. |
|
 |
Long service life:
Certified materials, balanced design on heat expansion areas, certified automated welding methods, design &
calculations in European norms and approved management, manufacture methods offers longer service times than ever.
Burner compatibility:
Special high-counter pressure, long balast tube burners not required. High efficiency, stable smooth and silent combustion is attained with burners that comply with EN 676 and EN 267.
Aesthetic appearance:
Boiler external jackets are protected against corrosion and environmental factors by following 3 features:
1. Hot dipped galvanised (GALVATITE ®) steel material.
2. Protective double layer special organic undercoat plating.
3. Special organic paint, with top layer protective and aesthetic plating (COLORCOAT ®).
Enviroment friendly:
No hazardous materials for environment such as; asbestos is not used in the boilers.
Technical Details (ACK2 Series)
Technical Details (ACK3 Series)
|
|
|
| |
| |
 |
|
Alarko Solid Fuel Fired Steel Boiler-Domestic |
| |
The flue gas is more easily evacuated in the boilers equipped with plate as compared to the classical types. The boelers equiped with plate creates less soot as compared to the boilers with pipe. No frequent cleaning is required. Cleaning is much easier as compared to the pipe types.
Modern Technology: Monoblock semi-cylindiric, steel body and fully welded consturuction durable against high pressure.
Full Quality Control: Post-production 100% hydraulic test at 4 bar pressure.
Appropriate Fuel: Lower calorific value should be minimum 6,000 kcal/kg and maximum 7,000 kcal/kg, with coal dimensions between 25 and 60 mm.
Excellent Isolation: Glass wool isolation of 6 cm thick with aluminium folio outer body.
|
|
 |
Aesthetic and Modern: Outer cassette iron sheet painted with electrostatic powder paint.
Ergonomic: Eassy installation, operation and maintenance.Easy acces to all parts.
Safe: 60-90°C thermostat for operation. 100°C limit thermostat with manuel reset for safety.
High Output: TSE and EN standards compliant nominal capacity and output.
Technical Details
|
|
|
| |
| |
 |
|
Alarko Solid Fuel Fired Steel Boiler-Central |
| |
Alarko Konforal Solid Fuel Fired Steel Boilers are of the semi-cylindrical structure with 3 passages, without turbulators. The side parts that serve as ash tray is cooled down with water in order to minimize the heat loss. The combustion air necessary for combustion is secured as forced with fan. The fuel consumption is low, as the efficiency is high.
Adequate draught chimney according to local codes is necessary for that the boiler operates at nominal capacity.
|
|
 |
Modern Technology: Monoblock semi-cylindiric, steel body and fully welded construction.
Full Quality Control: Post-production 100% hydraulic test at 4 bar pressure.
Appropriate Fuel: Lower calorific value should be minimum 6,000 kcal/kg and maximum 7,000 kcal/kg, with coal dimensions between 25 and 60 mm.
Excellent Isolation: Glass wool isolation of 6 cm thick with aluminium folio outer body.
Aesthetic and Modern: Outer cassette iron sheet painted with electrostatic powder paint.
Ergonomic: Easy installation, operation and maintenance. Easy acces to all parts.
Safe: 60-90°C thermostat for operation. 100°C limit thermostat with manual reset for safety.
High Output: TSE and EN standards compliant nominal capacity and output.
Technical Details
|
|
|
| |
| |
 |
|
Baykan Boiler |
| |
|
|
|
|
 |